model:YT-WSW
Italian imported microbial rapid detection instrument RVLM:Main features:1) Can detect solid, liquid, surface, paste, and slurry samples;2) The sample does not require any pre-proc···
  technical supportYuntang Technology
One click access to quotation WeChat Scan Code Add Technical EngineerWhatsApp:+86 18866361895
WeChat:+86 17865361250
Email:yuntang@foxmail.com
closeDetails
Picture and Text Introduction
Related Cases
Italian imported microbial rapid detection instrument RVLM:
Main features:
1) Can detect solid, liquid, surface, paste, and slurry samples;
2) The sample does not require any pre-processing during testing and can be directly thrown into the testing bottle;
3) Can automatically control incubation temperature and incubation time
4) The detection sample only requires 1ml/1g; 8 samples can be tested simultaneously at the same temperature;
5) High sensitivity can detect 1 target microorganism; Specific up to 99.999%;
6) Independently and continuously detect and record the number of microorganisms (CFU) in the bottle
7) Three simple operation steps, foolproof, no need for professional operators;
8) The instrument is portable and can be used for testing anytime, anywhere, 100% quantitative analysis, and can be directly connected to a computer to generate quantitative analysis and testing reports.
Detection range:
Total number of live bacteria
Escherichia coli/fecal coliforms/Escherichia coli/Escherichia coli O157, O111, O104, etc
Enterobacteriaceae
Staphylococcus aureus
Pseudomonas aeruginosa; Pseudomonas aeruginosa
Salmonella
Listeria monocytogenes
Enterococcus
Yeast
Application scope:
Hygiene control:
-Food (HACCP)
-Kitchen, tools, surfaces (HACCP)
-Water quality
-(CDC) Disease control, import and export inspection and quarantine
-Drugs and cosmetics
Closely related to our lives, such as:
Cafe, restaurant
Water source detection and water treatment plant
Analysis laboratory and HACCP diagnosis
Agricultural products and related processing companies
Pharmacy, pharmacy, cosmetics factory
Environmental monitoring agencies
Water distribution company
Consumer protection groups, business administration agencies
Indoor Air Conditioning Adjustment Company
Combining the advantages of traditional testing methods:
-Culture dish method
-Enzymatic method( β- Glucosidase analysis
-Immunoassay (antigen search)
-Genetic method (gene search)
No pre-processing is required for the test sample
-Liquid samples, solid samples, and surface samples do not require pre-treatment
Qualitative and quantitative analysis
-Matching detection machine: 100% quantitative analysis
-Visual interpretation: qualitative or semi quantitative analysis
Simple and convenient
-Three simple steps to obtain detection results
Rapid inspection
-It is 2-5 times faster than traditional testing methods
High sensitivity
-Can detect 1 target microorganism (theoretical extreme value)
High specificity
-Specific up to 99.999% (theoretical extreme)
The testing bottle is the laboratory
-Microbial testing bottles are always available
-Testing personnel who have not received strict professional training can also conduct testing anytime and anywhere
Safe disposal after use
-Same treatment as expired drugs
Microbial testing bottles are particularly suitable for rapid food testing in military, large-scale exhibitions, and other fields
Microbial rapid detection instrument RVLM:
-Simple, convenient, 100% quantitative analysis
-Can accommodate 8 samples at the same temperature.
-Can automatically control incubation temperature and incubation time
-Independently and continuously detect and record the number of microorganisms (CFU) in the bottle
Aseptic treatment after use
-Press the cap above the RVL microbial detection bottle
-Dispose of with peace of mind and safety (same as expired drugs)
If there is no RVLM microbial detector:
-After fully dissolving and mixing, incubate in a thermostat
(Incubate at appropriate temperature for appropriate time, please refer to the table above)
-Visual interpretation of qualitative or semi quantitative analysis results
Taking the coliform group as an example:
If the bacterial count is greater than 108CFU/ml, the color will turn yellow within 2 hours;
If the bacterial count is less than 102CFU/ml, the color will not turn yellow within 14 hours;
If the colony does not exist: the color remains the starting color after 18 hours
Or other intermediate colors (not turning yellow)
Obtain 100% quantitative detection results in three simple steps:
Step 1: Place the sample
-Open the bottle cap and add 11ml of sterile water
-Add 0.1-1.0ml (0.1-1.0g) of liquid (solid/surface) sample
-Close the bottle cap tightly
Step 2: Shake the bottle until the solvent is fully dissolved or mixed
(Fully dissolve or mix as shown in the right figure)
-If using an oscillator, it takes about 20 seconds;
Or shake vigorously with your hands, which takes about 2-3 minutes.
Step 3: Interpret the results at the appropriate time (please refer to the table on the left)
-Using RVLM microbial detector:
-After fully dissolving and mixing, immediately put it into the testing instrument
-Obtain 100% quantitative analysis results
WeChat:+86 17865361250
WhatsApp:+86 18866361895
Email:yuntangzhineng@foxmail.com
Copyright @ 2019-2022 Shandong Yuntang Intelligent Technology Co., Ltd All Rights Reserved. Copyright Source manufacturer of pesticide residue detector, food detector, bacteria detector