Microbial detector-Shandong Yuntang Intelligent Technology Co., Ltd

WhatsApp:
+86 18866361895

Microbial detector

model:YT-WSW

Italian imported microbial rapid detection instrument RVLM:Main features:1) Can detect solid, liquid, surface, paste, and slurry samples;2) The sample does not require any pre-proc···

  technical support

Yuntang Technology

One click access to quotation WeChat Scan Code Add Technical Engineer

WhatsApp:+86 18866361895

WeChat:+86 17865361250

Email:yuntang@foxmail.com

close

Details

Related Cases

Italian imported microbial rapid detection instrument RVLM:


Main features:

1) Can detect solid, liquid, surface, paste, and slurry samples;

2) The sample does not require any pre-processing during testing and can be directly thrown into the testing bottle;

3) Can automatically control incubation temperature and incubation time

4) The detection sample only requires 1ml/1g; 8 samples can be tested simultaneously at the same temperature;

5) High sensitivity can detect 1 target microorganism; Specific up to 99.999%;

6) Independently and continuously detect and record the number of microorganisms (CFU) in the bottle

7) Three simple operation steps, foolproof, no need for professional operators;

8) The instrument is portable and can be used for testing anytime, anywhere, 100% quantitative analysis, and can be directly connected to a computer to generate quantitative analysis and testing reports.


Detection range:

Total number of live bacteria

Escherichia coli/fecal coliforms/Escherichia coli/Escherichia coli O157, O111, O104, etc

Enterobacteriaceae

Staphylococcus aureus

Pseudomonas aeruginosa; Pseudomonas aeruginosa

Salmonella

Listeria monocytogenes

Enterococcus

Yeast


Application scope:

Hygiene control:

-Food (HACCP)

-Kitchen, tools, surfaces (HACCP)

-Water quality

-(CDC) Disease control, import and export inspection and quarantine

-Drugs and cosmetics


Closely related to our lives, such as:

Cafe, restaurant

Water source detection and water treatment plant

Analysis laboratory and HACCP diagnosis

Agricultural products and related processing companies

Pharmacy, pharmacy, cosmetics factory

Environmental monitoring agencies

Water distribution company

Consumer protection groups, business administration agencies

Indoor Air Conditioning Adjustment Company

Combining the advantages of traditional testing methods:

-Culture dish method

-Enzymatic method( β- Glucosidase analysis

-Immunoassay (antigen search)

-Genetic method (gene search)

No pre-processing is required for the test sample

-Liquid samples, solid samples, and surface samples do not require pre-treatment

Qualitative and quantitative analysis

-Matching detection machine: 100% quantitative analysis

-Visual interpretation: qualitative or semi quantitative analysis

Simple and convenient

-Three simple steps to obtain detection results

Rapid inspection

-It is 2-5 times faster than traditional testing methods

High sensitivity

-Can detect 1 target microorganism (theoretical extreme value)

High specificity

-Specific up to 99.999% (theoretical extreme)

The testing bottle is the laboratory

-Microbial testing bottles are always available

-Testing personnel who have not received strict professional training can also conduct testing anytime and anywhere

Safe disposal after use

-Same treatment as expired drugs

Microbial testing bottles are particularly suitable for rapid food testing in military, large-scale exhibitions, and other fields

Microbial rapid detection instrument RVLM:

-Simple, convenient, 100% quantitative analysis

-Can accommodate 8 samples at the same temperature.

-Can automatically control incubation temperature and incubation time

-Independently and continuously detect and record the number of microorganisms (CFU) in the bottle

Aseptic treatment after use

-Press the cap above the RVL microbial detection bottle

-Dispose of with peace of mind and safety (same as expired drugs)

If there is no RVLM microbial detector:

-After fully dissolving and mixing, incubate in a thermostat

(Incubate at appropriate temperature for appropriate time, please refer to the table above)

-Visual interpretation of qualitative or semi quantitative analysis results

Taking the coliform group as an example:

If the bacterial count is greater than 108CFU/ml, the color will turn yellow within 2 hours;

If the bacterial count is less than 102CFU/ml, the color will not turn yellow within 14 hours;

If the colony does not exist: the color remains the starting color after 18 hours

Or other intermediate colors (not turning yellow)

Obtain 100% quantitative detection results in three simple steps:

Step 1: Place the sample

-Open the bottle cap and add 11ml of sterile water

-Add 0.1-1.0ml (0.1-1.0g) of liquid (solid/surface) sample

-Close the bottle cap tightly

Step 2: Shake the bottle until the solvent is fully dissolved or mixed

(Fully dissolve or mix as shown in the right figure)

-If using an oscillator, it takes about 20 seconds;

Or shake vigorously with your hands, which takes about 2-3 minutes.

Step 3: Interpret the results at the appropriate time (please refer to the table on the left)

-Using RVLM microbial detector:

-After fully dissolving and mixing, immediately put it into the testing instrument

-Obtain 100% quantitative analysis results

Previous article:没有了! Next article:Mask microbiological detector
Contact Us

WeChat:+86 17865361250

WhatsApp:+86 18866361895

Email:yuntangzhineng@foxmail.com

Copyright @ 2019-2022 Shandong Yuntang Intelligent Technology Co., Ltd All Rights Reserved. Copyright Source manufacturer of pesticide residue detector, food detector, bacteria detector

Contact   WeChat atp荧光检测仪_微生物细菌检测仪_atp检测仪器 厂家 价格 -云唐科技

Professional Food Testing Engineer

24-hour online service

Submit requirements and quickly recommend suitable products for you

Technical consulting services, instrument price lists, and online answers to industry solutions.
微信咨询 微信咨询

WhatsApp

+86 18866361895
微信咨询 微信咨询

WeChat

微信咨询
回到顶部 回到顶部

TOP

liuyan  Leave us a message